Release Note 2016

MIKE URBAN

Introduction

Welcome to MIKE URBAN Release 2016. In this Release Note, you will find information about new features of MIKE URBAN, and what you need to know in order to install and get started with Release 2016.

MIKE URBAN is a flexible system for modeling and design of water distribution networks and collection systems for wastewater and storm water. MIKE URBAN is based on a database for storing network as well as hydraulic modeling data.

With MIKE URBAN you have:

System requirements

The recommended minimum system requirements are:

Operating systems Fully supported operating systems *
Windows 7 Professional Service Pack 1 (32 and 64 bit), Windows 8.1 Pro (64 bit), Windows 10 Pro (64 bit) and Windows Server 2012 R2 Standard (64 bit).

Non-supported but partially tested operating systems **
Windows 8.1 Pro (32 bit), Windows 10 Pro (32 bit) and Windows Server 2008 R2 Standard Service Pack 1 (64 bit).
Note that Release 2016 is the last release supporting 32 bit operating systems.
Processor x86 or x64, 2.2 GHz (or higher)
Memory (RAM) 2 GB (or higher)
Hard disk 40 GB (or higher)
Monitor SVGA, resolution 1024x768 in 16 bit colour
Graphics adapter 64 MB RAM (256 MB RAM or higher recommended), 24 bit true colour
File system NTFS
Software requirements .NET Framework 3.5 SP1 and .NET Framework 4.0 (Full Profile)

* Fully supported operating systems are systems that have been tested in accordance with MIKE's Quality Assurance procedures and where warranty and software maintenance agreement conditions apply.

** Non-supported but partially tested operating systems are systems, which are not officially supported by the MIKE software products. These operating systems have only undergone very limited testing for the purpose of MIKE software, but the software and key features are likely to work. Installation of MIKE software on a non-supported operating system is done so at the user's own risk. The MIKE software warranty and software maintenance agreement conditions do not apply for unsupported operating systems and DHI is under no obligation to provide assistance or troubleshooting for cases where the software is being used on a non-supported operating system.

Please note that single user installations are not allowed on server operating systems. Also, when running a fully supported operating system as a 'guest operating system' on a virtualisation platform, it is automatically downgraded to a non-supported operating system under the conditions provided above.

Installation

^ top

To install MIKE URBAN, please choose MIKE URBAN in the ‘MIKE Setup’ dialogue box that appears when inserting the MIKE software 2016 USB and clicking the Setup.exe or executing the Setup.exe file from the downloaded installation files. Press the ‘Install’ button to begin installation.

MIKE URBAN 2016 is based on ArcGIS 10.3. If you have ArcGIS versions prior to 10.3 installed, it will not be possible to keep these.

Licence file and dongle

^ top

To use MIKE URBAN in licenced mode, please follow these steps:

  1. You can retrieve the MIKE software licence file (DhiLicense.dat) via the Internet. This requires a working Internet connection and a valid e-mail address. The licence file can be retrieved in two ways:
    • During installation of the MIKE software
    • After installation of the MIKE software, by launching the DHI License Updater through the Windows Start menu
  2. To retrieve your licence file during installation of MIKE software, select ‘Local’ when prompted to ‘Select license type’. In the following dialogue box, select ‘Internet’. At the end of the installation process, you will be prompted to insert your DHI dongle. Insert the dongle and follow the on-screen instructions.
  3. To update your licence file using the License Updater, simply launch "Start -> Programs -> MIKE 2016 -> DHI License Updater" and follow the on-screen instructions. On Windows 8, search for DHI License Updater.
  4. Alternatively, the licence file can simply be copied to the \Program files\DHI\2016\License or Program files(x86)\DHI\2016\License directory.
  5. After completed installation, you should ensure that your hardware key is attached to the system.

Product invocation

^ top

Launch MIKE URBAN from the Windows Start menu.

Support

^ top

For general support, please see our FAQ.

If you experience any difficulties, or if you have any questions, you can contact Client Care by mail, e-mail, phone or fax:

Client Care
DHI
Agern Allé 5
DK-2970 Hørsholm
Denmark

mike@dhigroup.com
Tel: +45 4516 9333
Fax: +45 4516 9292

Or you can find your local Client Care with support in your local language here.

New features

^ top

Every new release of MIKE URBAN consists of new modules, new features or corrections to problems or significant inconsistencies discovered in previous releases. Please find short descriptions of the most significant new and exciting features in Release 2016 below.

Model manager

Module/type

New feature

Rainfall runoff
  • Added support for Low Impact Development: Bio-retention cell, porous pavement, infiltration trench, rain barrel, vegetative swale, rain garden, green roof
General
  • Based on ArcGIS 10.3
  • MIKE 1D is the default engnie for new projects
  • Tables related to flooding are included in scenario manager
Building and maintaining models
  • Editors for ECO Lab couplings for AD coupled to advanced process descriptions
  • ECO Lab template is included for modeling H2S concentration
  • New Soakaway node type with use defined infiltration for modeling green structures
  • Support for importing data from the ISYBAU format
  • Submodel Manager Tool for easy split and merge of models and sub-models
Collection System - MOUSE - MIKE 1D
MIKE 1D
Added support for Low Impact Development: Bio-retention cell, porous pavement, infiltration trench, rain barrel, vegetative swale, rain garden, green roof
MIKE 1D
Support for ECO Lab for AD coupled to advanced process descriptions
Collection System - SWMM5
General

Support for SWMM 5.1.009

Known defects and workarounds

^ top

No known defects or workarounds.

Fixed issues

 

Release 2016 Service Pack 3

Module/type

Error/Inconvenience/New feature

Status

 MIKE 1D
Infiltration flow and wetting loss reservoir have been improved for the Kinematic Wave (B) runoff model Fixed
 MIKE 1D
Improved handling of catchment with extremely low slopes. A limit of 1 per mille has been set as lower limit Fixed
 MIKE 1D
MIKE 1D MU-RR: RDI+A/B with dedicated rain has been assigned correctly Fixed
 MIKE 1D
The engine has been enhanced to extrapolate CRS section when water level are higher in open channels New Feature
 MIKE 1D
A validation check has been added, enforcing that Colebrook White is only valid for circular cross sections. Fixed
 MIKE 1D
Coupling of basin and soak-away nodes to 2D is now possible with MIKE1D Fixed
 MIKE 1D
Runoff model B result file has been optimized to create significantly smaller results and running faster by means smart dry time stepping implementation Fixed
Model Manager
An exception has been eliminated when importing links with topology ticked Fixed
Model Manager
Catchment connection wizard includes Soak-away nodes Fixed
Model Manager
Specification of units during import process has been enabled. Fixed
Model Manager
Calibration plots and reports tool has been updated to handle network res1D results. Fixed
Model Manager
Pipe Design Wizard has been enabled to create an ADP file for the mode “Individual” Fixed
Collection system
Problem with importing data from KMD2 files has been fixed. Fixed
Collection system
Import of SWMM5 DWF patterns with “hourly” and “weekend” types into MIKE URBAN have been corrected Fixed
Collection system
The tool to convert SWMM Interface files to CRF files has been updated. As well as a problem reading SWMM.out files in the SWMM converter has been fixed Fixed
2D Flooding
MIKE URBAN Flood can load dfs2 results file when the time zone is set to Sydney time, which caused some problems before. Fixed
2D Flooding
A problem with MIKE1D interpreting an internal node as an open boundary node  has been resolved Fixed
MOUSE engine
MOUSE Engine should issue an error message if the field ’Discharge coeff’ in the Orifice dialog is left empty Fixed
MOUSE engine
MOUSE/MSHE coupling has been updated Fixed
Water Distribution
Improved checked of program files. Fixed
Water Distribution
Handling of pressure units’ conversion has been improved. Fixed
Documentation
Updated information on LID control units. Fixed
 
Release 2016 Service Pack 2
^ top

Module/type

Error/Inconvenience/New feature

Status

Model Manager and MIKE 1D
  • Enhanced to handle all CRS X-Z OPEN type curves
  • Validation updates has been assigned to pump structures
  • Hydrological model B (kinematic wave) handling long timespans
  • Running Model A running long series of rain events
  • The entries simulation time is included in the job list created fil, the .mjl file has been improved.
Fixed
Collection system
  • Various issues in SWMM has been fixed which enables complete export of side-flow weirs setups
  • Catchment dialog grid has been redesigned to fit in different screen resolutions
Fixed
Collection system
Drainage for bio-retention cells is fully supported - LIDs New Feature
Documentation
Documentation regarding curb inlets (2D coupling) has been updated Fixed
General
  • Scenario Manager handling differences in datatypes between scenarios
  • The KMD2 time series bridge handling data with multiple digits
  • Result verification has been enabled to compare res1d with PRF files
Fixed
Model Configuration
Tool to apply and update errors when working with conflict flags Fixed
Project check tool
Soakaway type node is now supported and included New feature
Water Distribution
The algorithm for Water Hammer has been fixed to avoid oscillations and crashes while adding check valves in the analysis Fix
Release 2016 Service Pack 1
^ top

Module/type

Error/Inconvenience/New feature

Status

Model Manager and MIKE 1D
Added support for Low Impact Development: Bio-retention cell, porous pavement, infiltration trench, rain barrel, vegetative swale, rain garden, green roof New feature
GIS extensions
Unable to load DFS2 files into ArcMAP Fixed
Documentation
Missing link to MIKE URBAN dedicated ECOLab template in documentation index Fixed

Release 2016

Module/type

Error/Inconvenience/New feature

Status

Model Manager

Project check tool reporting non-critical cyclic profiles issues as error

Fixed
Flooding

It is possible to couple to non-existing cells when coupling to MIKE 21 FM

Fixed
MIKE1D engine

MIKE 1D cannot combine Colebrook-White resistance formulation with non-return valves

Fixed
Model manager

If MIKE URBAN is minimized and then closed it will re-open in minimized state

Fixed
Model manager

In the Weir editor, "Orientation" is enabled when "Discharge coeff." is set even though it is not used

Fixed
MIKE Powered by DHI - Agern Allé 5 - DK-2970 Hørsholm, Denmark - Tel: +45 4516 9200, Fax: +45 4516 9292